Reverberation Time in Open-Plan Workspaces: What Designers Should Calculate Early

Want your open-plan office to actually sound good?

Typically designers consider acoustics at the very end of a project. Furniture is selected. Ceiling is approved. Then the client moves in and…

The whole floor sounds like a train station.

Here’s the problem:

By then it’s costly and complicated to fix that echo. But go through some quick calculations at the beginning and you can prevent that headache altogether. And the biggest calculation of them all is reverberation time.

Time to dive in!

What’s inside:

  • What Is Reverberation Time?
  • Why Open-Plan Offices Struggle With Echo
  • The 3x Numbers To Calculate Early
  • A Quick Sabine Formula Example
  • Common Mistakes Designers Make

What Is Reverberation Time?

Reverberation time is the time it takes for a sound to “decay” in a room. More specifically, RT60 is the time it takes for a sound to decrease 60 decibels after the source has stopped emitting the sound.

Think about it like this…

Clap your hands in an empty warehouse and the echo lasts. Clap them in a room crammed with cushions and it vanishes.

That’s reverberation time in action.

Long reverberation times in offices cause telephone rings, laughs and keystrokes to reverberate. Speech becomes smeared. Concentration becomes difficult. Fatigue sets in more quickly.

Short reverberation time = a calmer, clearer workspace.

Why Open-Plan Offices Struggle With Echo.

Think of an open-plan office. Glass walls. Concrete floors. Ceiling tiles exposed to the heavens. Every surface is hard as rock. Did you know that when sound hits these surfaces, they don’t absorb it… they reflect it.

Then you add dozens of people talking at once.

Teams should not react this way. After two large companies made the move to open-desk offices, face-to-face interactions dropped by 70%. Employees plugged in their headphones and resorted to email.

So what can you actually do about it?

Treating the ceiling is important. But you also need absorption at ear level, where conversations are taking place. That’s the job of portable acoustic screens. Positioned between desks they can block the direct path of speech, whilst also absorbing some of the reflected sound. As they’re freestanding, you can easily move these acoustic panels when teams expand or layouts change. So they’re great for agile floor plans.

Pretty handy, right?

The thing is…. Screens are most effective when they’re used strategically. And strategy begins with some simple math upfront.

The 3x Numbers To Calculate Early

Before anything gets ordered, there are three numbers every designer should have on paper.

Room Volume

Begin with dimensions of the space. Volume = length x width x height in cubic metres.

Large rooms reverb longer. One of the biggest offenders is high ceilings. That “cool” exposed ceiling may be adding critical tenths of a second to your RT60.

Total Absorption

All surfaces absorb some sound. They just absorb differing amounts. The type of material determines how much sound is absorbed. Materials have an absorption coefficient ranging from 0 to 1:

  • 0 means the surface reflects everything (like glass)
  • 1 means it absorbs everything (like an open window)

Multiply each area by its coefficient.  Add them together.  The sum is the total absorption of the room in square metre sabins.

Target Reverberation Time

The next step is to decide what you want to achieve. Most acoustic consultants would advise aiming for somewhere between 0.4 and 0.8 seconds in open plan office areas. Rooms where people need to concentrate should be towards the bottom end of that spectrum.

Come to agreement on this target with the client upfront. It will set the standard for all decisions going forward.

A Quick Sabine Formula Example.

Now for the fun part. The Sabine formula ties all three numbers together:

RT60 = 0.161 × Volume ÷ Total Absorption

It looks scary, but it really is that simple. Here’s a quick walk through.

Imagine an open-plan office which is 20m long by 15m wide by 3m high. That’s a volume of 900 cubic metres.

You want your target RT to be 0.6 seconds. Rearrange the equation to solve for how much absorption you’ll need:

  1. Multiply 0.161 by 900 = 144.9
  2. Divide 144.9 by 0.6 = 241.5

So you need around 241.5 square metre sabins of absorption in that room.

Now compare that number to what is already in the room. If your hard surfaces only total 120 sabins, you have well over 120 sabins you need to make up. You can make up that difference by:

  • Acoustic ceiling tiles
  • Wall panels
  • Carpet and rugs
  • Soft furniture
  • Portable acoustic screens

The beauty of doing this now is that you know precisely how much treatment you require. No guessing. No overspending.

Common Mistakes Designers Make

Seasoned designers make acoustic mistakes too. Here are some of the biggest ones.

Leaving It Too Late

By far the biggest mistake designers make. As soon as the ceiling goes up and floors are down your options become limited quickly. Doing the math at the beginning allows you to play with material options before they’re set in stone.

Only Treating The Ceiling

Ceiling absorption will reduce reverberation. But will not prevent speech carrying directly from desk to desk. You need to combine ceiling treatment with portable acoustic screens at desk level to solve both issues.

Ignoring How People Feel

Numbers are important, but anecdotes are too. In this massive survey of 42,000 office workers, noise and lack of privacy were found to be the two biggest drivers of dissatisfaction with open-plan offices.

That’s a lot of unhappy staff.

Talk to those who will be using the space. Ask them where calls are taking place, where focused work occurs, etc. and design your treatment around that.

Forgetting The Space Will Change

Teams expand. Departments relocate. What works as a floorplan today may not next year. Permanent partitions leave you stuck. Moveable acoustic screens allow you to reconfigure your acoustics as your business needs.

Bringing It All Together

Possibly the easiest acoustic problem to fix  is reverberation time. But only if you catch it early. Just to review:

  • Measure the room volume
  • Work out the existing absorption
  • Set a target reverberation time
  • Use the Sabine formula to find the gap
  • Fill the gap with ceiling panels and portable acoustic screens

Do this before you start your project and you’ll save time, money and countless embarrassing calls from your client.

Figure out the numbers first… everything else about design will take care of itself.